View : 861 Download: 0
Digital breast tomosynthesis and breast ultrasound: Additional roles in dense breasts with category 0 at conventional digital mammography
- Title
- Digital breast tomosynthesis and breast ultrasound: Additional roles in dense breasts with category 0 at conventional digital mammography
- Authors
- Lee W.K.; Chung J.; Cha E.-S.; Lee J.E.; Kim J.H.
- Ewha Authors
- 차은숙; 이지은; 정진; 김정현
- SCOPUS Author ID
- 차은숙; 이지은; 정진; 김정현
- Issue Date
- 2016
- Journal Title
- European Journal of Radiology
- ISSN
- 0720-048X
- Citation
- European Journal of Radiology vol. 85, no. 1, pp. 291 - 296
- Keywords
- Breast; Dense breast; Digital breast tomosynthesis; Digital mammography; Ultrasound
- Publisher
- Elsevier Ireland Ltd
- Indexed
- SCIE; SCOPUS
- Document Type
- Article
- Abstract
- Purpose To compare the diagnostic performances of digital breast tomosynthesis (DBT) and ultrasound for the dense breasts with category 0 at conventional digital mammography. Materials and methods This retrospective study was approved by the institutional review board, and informed consent was waived. Among the 1103 patients who underwent screening digital mammography at our institution, 769 (69.7%) patients had dense breasts. Of the 769 patients, 229 (29.8%) lesions were categorized as 0. DBT, breast ultrasound and digital mammography were performed in 108 (47.2%) patients. BI-RADS final assessments for DBT and ultrasound were recorded. Categories 1-3 were clinically considered as benign, and categories 4 and 5 were clinically considered as malignant. The diagnostic performances of breast ultrasound and DBT were correlated with final pathologic reports or follow-up images. Results Among 108 lesions, 17 (15.7%) were malignant and 91 (84.3%) were benign. Sensitivity was 100% for both ultrasound (17/17) and DBT (17/17) and negative predictive value was also 100% for both ultrasound (49/49) and DBT (74/74). Specificity and positive predictive value for ultrasound were 53.9% (49/91) and 28.8% (17/59), respectively. Specificity and positive predictive value for DBT were 81.3% (74/91) and 50% (17/34), respectively. DBT showed higher diagnostic accuracy than that of breast ultrasound (DBT: 84.3%, 91/108; ultrasound: 61.1%, 66/108; p <0.001). The benign biopsy rate of DBT (50%, 17/34) was lower than that of ultrasound (71.2%, 42/59). Conclusion DBT showed better diagnostic performance than breast ultrasound for dense breasts with category 0. DBT may reduce the benign biopsy rate and short term follow-up. © 2015 Elsevier Ireland Ltd. All rights reserved.
- DOI
- 10.1016/j.ejrad.2015.09.026