View : 1410 Download: 379

Full metadata record

DC Field Value Language
dc.contributor.author박은정-
dc.date.accessioned2016-08-28T10:08:31Z-
dc.date.available2016-08-28T10:08:31Z-
dc.date.issued2012-
dc.identifier.issn1932-6203-
dc.identifier.otherOAK-9037-
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/222863-
dc.description.abstractBackground: The pronator drift test is widely used to detect mild arm weakness. We developed an application that runs on a handheld device to objectify the pronator drift test and investigated its feasibility in stroke patients. Methods: The iPronator application, which uses the built-in accelerometer in handheld devices, was developed. We enrolled acute ischemic stroke patients (n = 10) with mild arm weakness and healthy controls (n = 10) to validate the iPronator. In addition to conventional neurological examinations, the degree of average, maximum, and oscillation in drift and pronation were measured and compared using the iPronator. Follow-up tests using the iPronator were also conducted in the patient group one week later. Results: There was a strong correlation between the average degree of pronation and drift measured by the iPronator (r = 0.741, p<0.001). The degrees of average and maximum in pronation were greater in the patient group than in the control group [in average, 28.9°, interquartile range (IQR) 18.7-40.3 vs. 3.8° (IQR 0.3-7.5), p<0.001], in maximum, 33.0° (IQR 24.0-52.1) vs. 6.2° (IQR 1.4-9.4), p<0.001]. The degree of oscillation in pronation was not different between the groups (p = 0.166). In drift, the degrees of average, maximum, and oscillation were greater in the patient group. In stroke patients, a follow-up study at one week revealed improvements in the degrees of pronation and drift compared with baseline parameters. Conclusions: The iPronator can reliably detect mild arm weakness of stroke patients and was also useful in detecting functional recovery for one week in patients with acute stroke. © 2012 Shin et al.-
dc.languageEnglish-
dc.titleAn objective pronator drift test application (iPronator) using handheld device-
dc.typeArticle-
dc.relation.issue7-
dc.relation.volume7-
dc.relation.indexSCIE-
dc.relation.indexSCOPUS-
dc.relation.journaltitlePLoS ONE-
dc.identifier.doi10.1371/journal.pone.0041544-
dc.identifier.wosidWOS:000306751300054-
dc.identifier.scopusid2-s2.0-84864228806-
dc.author.googleShin S.-
dc.author.googlePark E.-
dc.author.googleLee D.H.-
dc.author.googleLee K.-J.-
dc.author.googleHeo J.H.-
dc.author.googleNam H.S.-
dc.contributor.scopusid박은정(23390177000;55851944423)-
dc.date.modifydate20230328112008-


qrcode

BROWSE