Real-time in vivo simultaneous measurements of nitric oxide and oxygen using an amperometric dual microsensor

Title
Real-time in vivo simultaneous measurements of nitric oxide and oxygen using an amperometric dual microsensor
Authors
Park S.S.Hong M.Song C.-K.Jhon G.-J.Lee Y.Suh M.
Ewha Authors
전길자이영미
SCOPUS Author ID
전길자scopus; 이영미scopus
Issue Date
2010
Journal Title
Analytical Chemistry
ISSN
0003-2700JCR Link
Citation
Analytical Chemistry vol. 82, no. 18, pp. 7618 - 7624
Indexed
SCI; SCIE; SCOPUS WOS scopus
Document Type
Article
Abstract
This paper reports a real-time study of the codynamical changes in the release of endogenous nitric oxide (NO) and oxygen (O 2) consumption in a rat neocortex in vivo upon electrical stimulation using an amperometric NO/O 2 dual microsensor. Electrical stimulation induced transient cerebral hypoxia due to the increased metabolic demands that were not met by the blood volume inside the stimulated cortical region. A NO/O 2 dual microsensor was successfully used to monitor the pair of real-time dynamic changes in the tissue NO and O 2 contents. At the onset of electrical stimulation, there was an immediate decrease in the cortical tissue O 2 followed by a subsequent increase in the cortical tissue NO content. The averages of the maximum normalized concentration changes induced by the stimulation were a 0.41 (±0.04)-fold decrease in the O 2 and a 3.6 (±0.9)-fold increase in the NO concentrations when compared with the corresponding normalized basal levels. The peak increase in NO was always preceded by the peak decrease in O 2 in all animals (n = 11). The delay between the maximum decrease in O 2 and the maximum increase in NO varied from 3.1 to 54.8 s. This rather wide variation in the temporal associations was presumably attributed to the sparse distribution of NOS-containing neurons and the individual animal's differences in brain vasculatures, which suggests that a sensor with fine spatial resolution is needed to measure the location-specific real-time NO and O 2 contents. In summary, the developed NO/O 2 dual microsensor is effective for measuring the NO and O 2 contents in vivo. This study provides direct support for the dynamic role of NO in regulating the cerebral hemodynamics, particularly related to the tissue oxygenation. © 2010 American Chemical Society.
DOI
10.1021/ac1013496
Appears in Collections:
자연과학대학 > 화학·나노과학전공 > Journal papers