View : 510 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author은효원-
dc.date.accessioned2016-08-28T11:08:53Z-
dc.date.available2016-08-28T11:08:53Z-
dc.date.issued2005-
dc.identifier.issn0278-4297-
dc.identifier.otherOAK-2747-
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/219574-
dc.description.abstractObjective. The purpose of this research was to determine the feasibility of renal perfusion imaging by means of harmonic sonography with a microbubble contrast agent for the evaluation of renal perfusion after renal transplantation compared with technetium Tc 99m diethylenetriamine pentaacetic acid ( 99mTc-DTPA) scans. Methods. During a 10-month period, 100 patients with renal transplantation that included normal perfusion (n = 68) and delayed perfusion including chronic rejection (n = 19), acute rejection (n = 9), arterial stenosis (n = 2), and urinary stricture (n = 2) underwent sonographic renal perfusion imaging and 99mTc-DTPA scans. Sonographic images were obtained every 3 seconds for a total of 3 minutes after administration of a bolus injection of 4 g of the microbubble contrast agent at a concentration of 300 mg/mL. Sonographic renal perfusion images were converted into a renal perfusion curve, and the calculated time at the peak of the curve (T peak) was compared with that of the 99mTc-DTPA scan. Results. The Tpeak with the 99mTc-DTPA scan was 14.9 seconds in the normal group and 33 seconds in the delayed perfusion group. The Tpeak on sonographic renal perfusion images was 25 seconds in the normal group and 44.8 seconds in the delayed perfusion group. Sonographic renal perfusion images showed good correlation with the 99mTc-DTPA scan (r = 0.74; P = .0001). The cutoff value of the Tpeak on sonographic renal perfusion images was 35 seconds (sensitivity = 85%; specificity = 90%). Conclusions. The renal perfusion images obtained by means of harmonic sonography with a microbubble contrast agent constitute an effective sonographic technique for the evaluation of renal perfusion abnormalities after renal transplantation compared with a 99mTc-DTPA scan. © 2005 by the American Institute of Ultrasound in Medicine.-
dc.languageEnglish-
dc.titleClinical use of renal perfusion imaging by means of harmonic sonography with a microbubble contrast agent in patients after renal transplantation: Preliminary study-
dc.typeArticle-
dc.relation.issue6-
dc.relation.volume24-
dc.relation.indexSCI-
dc.relation.indexSCIE-
dc.relation.indexSCOPUS-
dc.relation.startpage755-
dc.relation.lastpage762-
dc.relation.journaltitleJournal of Ultrasound in Medicine-
dc.identifier.wosidWOS:000229461900003-
dc.identifier.scopusid2-s2.0-19544379333-
dc.author.googleKim J.H.-
dc.author.googleEun H.W.-
dc.author.googleLee H.J.-
dc.author.googleGoo D.E.-
dc.author.googleChoi D.L.-
dc.contributor.scopusid은효원(7801680142;7005700556)-
dc.date.modifydate20230307105844-
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE