View : 528 Download: 0

Comparison of Customized Abutments Made from Titanium and a Machinable Precious Alloy

Title
Comparison of Customized Abutments Made from Titanium and a Machinable Precious Alloy
Authors
Lee, Jee-HoPark, Ji-ManPark, Eun-JinKoak, Jai-YoungKim, Seong-KyunHeo, Seong-Joo
Ewha Authors
박은진
SCOPUS Author ID
박은진scopus
Issue Date
2016
Journal Title
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS
ISSN
0882-2786JCR Link

1942-4434JCR Link
Citation
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS vol. 31, no. 1, pp. 92 - 100
Keywords
customized abutmentcyclic loadingdental implantsdetorque valueimplant-abutment gap
Publisher
QUINTESSENCE PUBLISHING CO INC
Indexed
SCIE; SCOPUS WOS
Document Type
Article
Abstract
Purpose: To investigate the clinical usefulness, a customized abutment produced with the Pd-Ag-In alloy was compared with a customized abutment produced with the conventional titanium alloy for discoloration and mechanical accuracy. Materials and Methods: Discoloration and resistance to corrosion of the Pd-Ag-In alloy were evaluated using chemical solutions. Marginal adaptation of internal-type implants and abutments was compared using 10 titanium abutments and 10 Pd-Ag-In abutments using a surface measuring system. A detorque test was performed on 12 implant-abutment complexes of each control and experimental group to investigate screw joint stability. Cyclic loading simulating a human's mastication movement for 1 year was applied after 30 Ncm initial tightening, and the removal torque was measured using a digital torque gauge. The noninferiority test was conducted to compare the Pd-Ag-In alloy with a titanium abutment with a 10% margin. Results: The Pd-Ag-In alloy had a warm yellow color and displayed stable resistance to discoloration and corrosion, resulting in an advantageous esthetic property. When compared to the titanium alloy, it did not show noninferiority with respect to the gap between the implant and the abutment; the gap was approximately 13.3 mu m on average, which was not significantly different from those observed in previous studies. After long-term use, it displayed statistically significant noninferiority in the removal torque value compared to the titanium group. Conclusion: The Pd-Ag-In alloy-based customized abutment had good mechanical properties of the implant-abutment complex as well as a superior esthetic property, and can provide favorable outcomes in anterior implant restoration.
DOI
10.11607/jomi.4102
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE