View : 695 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author전윤식-
dc.contributor.author김민지-
dc.date.accessioned2016-08-27T04:08:49Z-
dc.date.available2016-08-27T04:08:49Z-
dc.date.issued2016-
dc.identifier.issn2234-7518-
dc.identifier.issn2005-372X-
dc.identifier.otherOAK-16362-
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/217988-
dc.description.abstractObjective: The purpose of this study was to compare the precision of three-dimensional (3D) images acquired using iTero (R) (Align Technology Inc., San Jose, CA, USA) and Trios (R) (3Shape Dental Systems, Copenhagen, Denmark) digital intraoral scanners, and to evaluate the effects of the severity of tooth irregularities and scanning sequence on precision. Methods: Dental arch models were fabricated with differing degrees of tooth irregularity and divided into 2 groups based on scanning sequence. To assess their precision, images were superimposed and an optimized superimposition algorithm was employed to measure any 3D deviation. The t-test, paired t-test, and one-way ANOVA were performed (p < 0.05) for statistical analysis. Results: The iTero (R) and Trios (R) systems showed no statistically significant difference in precision among models with differing degrees of tooth irregularity. However, there were statistically significant differences in the precision of the 2 scanners when the starting points of scanning were different. The iTero (R) scanner (mean deviation, 29.84 12.08 mu m) proved to be less precise than the Trios (R) scanner (22.17 +/- 4.47 mu m). Conclusions: The precision of 3D images differed according to the degree of tooth irregularity, scanning sequence, and scanner type. However, from a clinical standpoint, both scanners were highly accurate regardless of the degree of tooth irregularity.-
dc.languageEnglish-
dc.publisherKOREAN ASSOC ORTHODONTISTS-
dc.subjectThree-dimensional scanner-
dc.subjectDigital models-
dc.subjectDental cast analysis-
dc.subjectThree-dimensional diagnosis and treatment planning-
dc.titleA comparison of the precision of three-dimensional images acquired by 2 digital intraoral scanners: effects of tooth irregularity and scanning direction-
dc.typeArticle-
dc.relation.issue1-
dc.relation.volume46-
dc.relation.indexSCIE-
dc.relation.indexSCOPUS-
dc.relation.startpage3-
dc.relation.lastpage12-
dc.relation.journaltitleKOREAN JOURNAL OF ORTHODONTICS-
dc.identifier.doi10.4041/kjod.2016.46.1.3-
dc.identifier.wosidWOS:000369878400002-
dc.identifier.scopusid2-s2.0-84955472131-
dc.author.googleAnh, Ji-won-
dc.author.googlePark, Ji-Man-
dc.author.googleChun, Youn-Sic-
dc.author.googleKim, Miae-
dc.author.googleKim, Minji-
dc.contributor.scopusid전윤식(7202638291)-
dc.contributor.scopusid김민지(57201330607)-
dc.date.modifydate20221123093757-
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE