View : 641 Download: 0

Identification and quantification of seven volatile n-nitrosamines in cosmetics using gas chromatography/chemical ionization-mass spectrometry coupled with head space-solid phase microextraction

Title
Identification and quantification of seven volatile n-nitrosamines in cosmetics using gas chromatography/chemical ionization-mass spectrometry coupled with head space-solid phase microextraction
Authors
Choi, Na RaeKim, Yong PyoJi, Won HyunHwang, Geum-SookAhn, Yun Gyong
Ewha Authors
김용표
SCOPUS Author ID
김용표scopus
Issue Date
2016
Journal Title
TALANTA
ISSN
0039-9140JCR Link

1873-3573JCR Link
Citation
TALANTA vol. 148, pp. 69 - 74
Keywords
N-nitrosaminesCosmeticsGas chromatography/Chemical Ionization-Mass Spectrometry (GC/CI-MS)Head space-solid phase microextraction (HS-SPME)Accurate mass
Publisher
ELSEVIER SCIENCE BV
Indexed
SCI; SCIE; SCOPUS WOS scopus
Document Type
Article
Abstract
An analytical method was developed for the identification and quantification of seven volatile n-nitrosamines (n-nitrosodimethylamine [NDMA], n-nitrosoethylmethylamine [NMEA], n-nitrosodiethylamine [NDEA], n-nitrosodipropylamine [NDPA], n-nitrosodibutylamine [NDBA], n-nitrosopiperidine [NPIP], and n-nitrosopyrrolidine [NPYRD]) in water insoluble cream type cosmetics. It was found that the head space-solid phase microextraction (HS-SPME) was suitable for extraction, clean up, and pre-concentration of n-nitrosamines in the cream type samples so its optimal conditions were investigated. Identification and quantification of n-nitrosamines using single quadrupole gas chromatography/mass spectrometry (GC/MS) in chemical ionization (CI) mode were carried out with accurate mass measurements. Their accurate masses of protonated molecular ions were obtained within 10 mDa of the theoretical masses when sufficiently high signal was acquired from the unique calibration method using mass and isotope accuracy. For the method validation of quantification, spiking experiments were carried out to determine the linearity, recovery, and method detection limit (MDL) using three deuterated internal standards. The average recovery was 79% within 20% relative standard deviation (RSD) at the concentration of 50 ng/g. MDLs ranged from 0.46 ng/g to 36.54 ng/g, which was satisfactory for the directive limit of 50 ng/g proposed by the European Commission (EC). As a result, it was concluded that the method could be provided for the accurate mass screening, confirmation, and quantification of n-nitrosamines when applied to cosmetic inspection. (C) 2015 Elsevier B.V. All rights reserved.
DOI
10.1016/j.talanta.2015.10.045
Appears in Collections:
공과대학 > 화공신소재공학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE