View : 614 Download: 0

Combined Algorithm Using a Poor Increase in Inferior P-Wave Amplitude During Sympathetic Stimulation and Sinus Node Recovery Time for the Diagnosis of Sick Sinus Syndrome

Title
Combined Algorithm Using a Poor Increase in Inferior P-Wave Amplitude During Sympathetic Stimulation and Sinus Node Recovery Time for the Diagnosis of Sick Sinus Syndrome
Authors
Park, Jin-KyuPark, JunbeomUhm, Jae-SunPak, Hui-NamLee, Moon-HyoungJoung, Boyoung
Ewha Authors
박준범
SCOPUS Author ID
박준범scopus
Issue Date
2015
Journal Title
CIRCULATION JOURNAL
ISSN
1346-9843JCR Link

1347-4820JCR Link
Citation
CIRCULATION JOURNAL vol. 79, no. 10, pp. 2148 - +
Keywords
Corrected sinus node recovery timeP-wave amplitudeSick sinus syndromeSinus node dysfunctionSympathetic stimuli
Publisher
JAPANESE CIRCULATION SOC
Indexed
SCI; SCIE; SCOPUS WOS scopus
Document Type
Article
Abstract
Background: This study sought to evaluate whether a poor increase in inferior P-wave amplitude during sympathetic stimulation might be a helpful diagnostic tool for sick sinus syndrome (SSS). Methods and Results: Three-dimensional electroanatomic mapping of the right atrium, inferior P-wave amplitude and conventional corrected sinus node recovery time (CSNRT) were compared in 112 consecutive atrial fibrillation (AF) patients with (n=21) and without SSS (n=91). The significant cranial shift of earliest activation site (EAS) (the distance from the superior vena cava to the EAS: 11.1 vs. 5.9 mm, P<0.001) and the increases of inferior P-wave amplitudes during isoproterenol infusion (all P<0.001) were observed in patients without SSS. However, cranial shift of EAS (16.5 vs. 14.2 mm, P=0.375) and P-wave amplitude increases were not observed in those with SSS. Although CSNRT >550 ms showed a sensitivity of 50% and specificity of 84% for diagnosing SSS, poor increases of P-waves amplitude in lead aVF (<0.1 mV) during isoproterenol infusion showed an improved sensitivity of 71% and specificity of 89%. Finally, the combined algorithm using CSNRT >550 ms and poor increase of P-waves amplitude in lead aVF showed more improved diagnostic accuracy (sensitivity 89%, specificity 75%). Conclusions: A combined algorithm using inferior P-wave amplitude showed improved performance for the diagnosis of SSS compared with CSNRT >550 ms alone.
DOI
10.1253/circj.CJ-15-0561
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE