View : 614 Download: 0
Combined Algorithm Using a Poor Increase in Inferior P-Wave Amplitude During Sympathetic Stimulation and Sinus Node Recovery Time for the Diagnosis of Sick Sinus Syndrome
- Title
- Combined Algorithm Using a Poor Increase in Inferior P-Wave Amplitude During Sympathetic Stimulation and Sinus Node Recovery Time for the Diagnosis of Sick Sinus Syndrome
- Authors
- Park, Jin-Kyu; Park, Junbeom; Uhm, Jae-Sun; Pak, Hui-Nam; Lee, Moon-Hyoung; Joung, Boyoung
- Ewha Authors
- 박준범
- SCOPUS Author ID
- 박준범
- Issue Date
- 2015
- Journal Title
- CIRCULATION JOURNAL
- ISSN
- 1346-9843
1347-4820
- Citation
- CIRCULATION JOURNAL vol. 79, no. 10, pp. 2148 - +
- Keywords
- Corrected sinus node recovery time; P-wave amplitude; Sick sinus syndrome; Sinus node dysfunction; Sympathetic stimuli
- Publisher
- JAPANESE CIRCULATION SOC
- Indexed
- SCI; SCIE; SCOPUS
- Document Type
- Article
- Abstract
- Background: This study sought to evaluate whether a poor increase in inferior P-wave amplitude during sympathetic stimulation might be a helpful diagnostic tool for sick sinus syndrome (SSS). Methods and Results: Three-dimensional electroanatomic mapping of the right atrium, inferior P-wave amplitude and conventional corrected sinus node recovery time (CSNRT) were compared in 112 consecutive atrial fibrillation (AF) patients with (n=21) and without SSS (n=91). The significant cranial shift of earliest activation site (EAS) (the distance from the superior vena cava to the EAS: 11.1 vs. 5.9 mm, P<0.001) and the increases of inferior P-wave amplitudes during isoproterenol infusion (all P<0.001) were observed in patients without SSS. However, cranial shift of EAS (16.5 vs. 14.2 mm, P=0.375) and P-wave amplitude increases were not observed in those with SSS. Although CSNRT >550 ms showed a sensitivity of 50% and specificity of 84% for diagnosing SSS, poor increases of P-waves amplitude in lead aVF (<0.1 mV) during isoproterenol infusion showed an improved sensitivity of 71% and specificity of 89%. Finally, the combined algorithm using CSNRT >550 ms and poor increase of P-waves amplitude in lead aVF showed more improved diagnostic accuracy (sensitivity 89%, specificity 75%). Conclusions: A combined algorithm using inferior P-wave amplitude showed improved performance for the diagnosis of SSS compared with CSNRT >550 ms alone.
- DOI
- 10.1253/circj.CJ-15-0561
- Appears in Collections:
- 의과대학 > 의학과 > Journal papers
- Files in This Item:
There are no files associated with this item.
- Export
- RIS (EndNote)
- XLS (Excel)
- XML