View : 786 Download: 0

Full metadata record

DC Field Value Language
dc.contributor.author임수미*
dc.contributor.author이정경*
dc.contributor.author박은미*
dc.contributor.author류인균*
dc.contributor.author이정현*
dc.date.accessioned2016-08-27T04:08:54Z-
dc.date.available2016-08-27T04:08:54Z-
dc.date.issued2015*
dc.identifier.issn0374-4884*
dc.identifier.issn1976-8524*
dc.identifier.otherOAK-15403*
dc.identifier.urihttps://dspace.ewha.ac.kr/handle/2015.oak/217460-
dc.description.abstractObjectives: Although small-bore high-field magnets are useful for research in small rodent models, this technology, however, has not been easily accessible to most researchers. This current study, thus, tried to evaluate the usability of 4CH-Mouse coil (Philips Healthcare, Best, the Netherlands) for preclinical investigations in clinical 3T MR scan environment. We evaluated the effects of ischemic preconditioning (IP) in the mouse stroke model with clinical 3T MR scanner and 4CH-Mouse coil. Materials and Methods: Experiments were performed on male C57BL/6 mice that either received the IP or sham operation (control). Three different MR sequences including diffusion weighted images (DWI), T2-weighted images (T2WI), and fluid attenuated inversion recovery (FLAIR) were performed on the mouse brains following 24, 72 hours of middle cerebral artery occlusion (MCAO) and analyzed for infarct lesions. Results: The images showed that the IP-treated mouse brains had significantly smaller infarct volumes compared to the control group. Of the MR sequences employed, the T2WI showed the highest level of correlations with postmortem infarct volume measurements. Conclusions: The clinical 3T MR scanner turned out to have a solid potential as a practical tool for imaging small animal brains. MR sequences including DWI, T2WI, FLAIR were obtained with acceptable resolution and in a reasonable time constraint in evaluating a mouse stroke model brain.*
dc.languageEnglish*
dc.publisherKOREAN PHYSICAL SOC*
dc.subjectIschemic preconditioning*
dc.subjectCerebral infarct*
dc.subjectMagnetic resonance imaging*
dc.titleMR images of mouse brain using clinical 3T MR scanner and 4CH-Mouse coil*
dc.typeArticle*
dc.relation.issue1*
dc.relation.volume67*
dc.relation.indexSCI*
dc.relation.indexSCIE*
dc.relation.indexSCOPUS*
dc.relation.indexKCI*
dc.relation.startpage237*
dc.relation.lastpage242*
dc.relation.journaltitleJOURNAL OF THE KOREAN PHYSICAL SOCIETY*
dc.identifier.doi10.3938/jkps.67.237*
dc.identifier.wosidWOS:000358616200038*
dc.identifier.scopusid2-s2.0-84938348135*
dc.author.googleLim, Soo Mee*
dc.author.googlePark, Eun Mi*
dc.author.googleLyoo, In Kyoon*
dc.author.googleLee, Junghyun*
dc.author.googleHan, Bo Mi*
dc.author.googleLee, Jeong Kyong*
dc.author.googleBin Lee, Su*
dc.contributor.scopusid임수미(26643435000)*
dc.contributor.scopusid이정경(35316081600)*
dc.contributor.scopusid박은미(35933416400)*
dc.contributor.scopusid류인균(55664289900)*
dc.date.modifydate20240220114752*
Appears in Collections:
의과대학 > 의학과 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE