dc.description.abstractAimThe aim of this study was to clarify the method of the Duncan-Ely test and to estimate its interobserver reliability and validity by comparing it with three-dimensional gait analysis (3DGA). MethodThis study included 36 consecutive ambulatory patients with cerebral palsy (CP) who underwent preoperative 3DGA. The Duncan-Ely test was performed during three different velocities (slow, gravity, and fast). The interobserver reliability was assessed by three examiners. The results of the test were compared with kinematic variables derived from the gait analysis to assess the sensitivity and specificity of the test. The cut-off value was determined at the point of trade-off between the highest sensitivity and specificity. ResultsThe intraclass correlation coefficient measuring interobserver reliability of the Duncan-Ely test was greatest during fast velocity (0.819). The sensitivity and specificity of the test during gravity velocity for knee range of motion total were 63.0% and 100% respectively, with a cut-off value of 78.3 degrees. The sensitivity and specificity of the test during fast velocity for knee range of motion total were 66.7% and 100% respectively, with a cut-off value of 65 degrees. InterpretationThe Duncan-Ely test shows excellent reliability in fast knee-flexion velocity, and good sensitivity and specificity compared with 3DGA during physical examination as a preoperative assessment of rectus femoris spasticity in patients with CP. What this paper adds <list list-type="bulleted" id="dmcn12761-list-0001"> The interobserver reliability of the Duncan-Ely test was greatest during fast velocity. The sensitivity and specificity of the Duncan-Ely test were greatest during fast velocity. This article is commented on by Stott on pages 895-896 of this issue.-
dc.languageEnglish-
dc.publisherWILEY-BLACKWELL-
dc.titleReliability and validity of the Duncan-Ely test for assessing rectus femoris spasticity in patients with cerebral palsy-
dc.typeArticle-
dc.relation.issue10-
dc.relation.volume57-
dc.relation.indexSCIE-
dc.relation.indexSCOPUS-
dc.relation.startpage963-
dc.relation.lastpage968-
dc.relation.journaltitleDEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY-
dc.identifier.doi10.1111/dmcn.12761-
dc.identifier.wosidWOS:000361236000018-
dc.identifier.scopusid2-s2.0-84940964235-
dc.author.googleLee, Seung Yeol-
dc.author.googleSung, Ki Hyuk-
dc.author.googleChung, Chin Youb-
dc.author.googleLee, Kyoung Min-
dc.author.googleKwon, Soon-Sun-
dc.author.googleKim, Tae Gyun-
dc.author.googleLee, Sang Hyeong-
dc.author.googleLee, In Hyeok-
dc.author.googlePark, Moon Seok-
dc.contributor.scopusid이승열(55370165300)-
dc.date.modifydate20190809081000-
Appears in Collections:
의료원 > 의료원 > Journal papers
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE