View : 978 Download: 0

하악구치부 임플란트 치관에서 협설 캔틸레버 양에 따른 응력분포에 관한 3차원 유한요소 분석

Title
하악구치부 임플란트 치관에서 협설 캔틸레버 양에 따른 응력분포에 관한 3차원 유한요소 분석
Other Titles
Three-dimensional finite element analysis of stress distribution according to the length of cantilever in implant crown placed at the molar region of the mandible
Authors
김현주
Issue Date
2010
Department/Major
임상치의학대학원 임상치의학과임플란트치의학전공
Publisher
이화여자대학교 임상치의학대학원
Degree
Master
Advisors
박지만
Abstract
Purpose : In case of large horizontal discrepancy of upper and lower alveolar ridge due to severe ridge resorption, buccal cantilever crown is usually an unavoidable treatment modality. This study was conducted to find out the clinical criteria for the placement of the aforementioned implant crown. Materials and Methods : For the single molar missing mandible model, external connection type implant (diameter 5.0mm, length 11mm) was installed. The thickness of cortical bone was 2.0mm, the implant fixtures were completely fixed, and cortical and cancellous bone were homogeneous. Following experimental conditions were established: at the point on the occlusal table, 0 to 7mm buccally apart from implant center, (1) vertical load and (2) 30° degree oblique load of 100N was applied and stress around bone and abutment was analyzed. Finite element analysis was performed utilizing COSMOS Works(Solid works Inc, USA). The representative data of von Mises stress and Principal stress were compared between the 2 groups. Results : From the finite element model, the following results were drawn. (1) values of von Mises stress on cortical bone, cancellous bone, fixture, abutment and screw at the vertical loads increased according to the offset length. (2) values of von Mises stress on cortical bone at the 30° degree the buccal aspect oblique loads decreased according to the offset length. (3) values of von Mises stress on implant components at the 30° degree the buccal aspect oblique loads decreased to the 5mm offset according to the offset length. (4) value of von Mises stress on implant components at the 30° degree the buccal aspect oblique load at the 5mm offset is the lowest. (5) values of von Mises stress on implant components at the 30° degree the buccal aspect oblique loads increased from 5mm to the 7mm offset according to the offset length. Conclusion : The results of this study suggest that for the patient with atrophied alveolar ridge following the loss of mandibular molar teeth, values of von Mises stress on cortical bone, cancellous bone, fixture, abutment and screw at the vertical loads increased according to the offset length and values of von Mises stress on implant components at the 30° degree the buccal aspect oblique loads at the 5mm offset is the lowest. Further studies for the various crown height and numbers of occusal points are needed to generalize the conclusion of present study.;광범위한 치조골 흡수로 인해 상하악의 협설 방향으로의 치조제 위치 변위가 큰 경우 임플란트 보철물을 제작하기 위해 어쩔 수 없이 가공치의 협설 길이를 증가시켜 캔틸레버를 길게 주는 보철물을 제작해야 하는 경우가 있으며, 이러한 경우 임플란트와 치조골에 미치는 영향과 이에 따른 임상적 기준에 관한 연구는 아직 많이 이루어지지 않은 실정이다. 본 연구는 하악 구치의 전산화단층촬영 스캐닝 이미지를 이용하여 치밀골의 두께가 2mm인 3차원 하악골 모델을 형성하고, 직경 5.0mm, 길이 11mm 외측 연결 방식의 임플란트인 USⅡ(Osstem Implant, Busan, Korea)를 사용하였다. 가공치의 중심과 임플란트 중심과의 다양한 편심부하(offset)를 고려하기 위해 협측 방향으로 4mm 증가된 가공치 모델을 제작하였다. 그리고 수직하중 100N이 임플란트 중심과 협측 1mm씩 편심 부하된 위치에 가해진 경우와 협측에서 설측 방향으로 30° 경사 하중 100N이 임플란트 중심과 협측 1mm씩 편심 부하된 위치에 가해진 경우를 3D 유한요소법을 이용하여 치조골(피질골, 해면골)과 임플란트 고정체, 지대주, 나사에 발생하는 von-Mises stress와 주응력 분포를 관찰하여 비교 분석하였다 수직하중의 위치가 1mm 씩 편심 부하 될수록 골과 임플란트에 걸리는 굽힘 모멘트가 증가하여 응력이 편심 거리에 비례해서 선형적으로 증가한 반면, 경사하중이 임플란트 중심에서 협측 방향으로 6mm까지 편심된 경우에는 골에 걸리는 응력이 점점 줄어 들고 7mm 편심된 경우에 거의 균일한 압축응력이 나타났다. 또한 임플란트에 걸리는 응력은 4mm 편심될 때까지 응력이 감소하다가 5mm 편심 위치에서 가장 작은 응력이 나타나고 7mm 까지 편심부하가 증가하면서 응력이 증가하였다.
Fulltext
Show the fulltext
Appears in Collections:
임상치의학대학원 > 임플란트치의학전공 > Theses_Master
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

BROWSE